MICROBIAL AIR SAMPLERS


MICROBIOLOGICAL MONITORING OF AIR IN CLEANROOMS


Microbial Air Samplers

PORTABLE MICROBIAL AIR SAMPLER ACTIVECOUNT

The high-performance microbial air samplers of the ActiveCount100 series are based on the principle of the impaction method. The air flow is directed onto a petri dish containing agar. After the collection cycle, the Petri dish is incubated and the colony-forming units (CFU) are counted. The air sampler is portable, compact, of high quality and features user-friendly software. Measuring cycles and intervals can be easily programmed on the large color touchscreen. The impactor head is exchangeable and autoclavable. The optional remote probe head minimizes disruptions to the laminar air flow within biosafety workbenches and laminar flow boxes.

  • d50 collection efficiency of 1 micron.
  • Hepa filtered air outlet avoids using air that has already been sampled.
  • Autoclavable collection head, dust cover and removable petri dish holder.
  • Robust stainless steel housing with rounded edges for use in clean rooms; can be disinfected with conventional cleaning agents.
  • Hot keys for different sampling modes with freely adjustable sample volumes.
  • Programmable: 8 sampling volumes, 50 user names, 400 location names.
  • Freely selectable delay time allows the operator to move away from the air sampler.
  • Measurement settings can be protected with a password.
  • 24 VAC adapter or up to 10h battery use.
  • Optional pressure adapter: Analysis of microbiological contamination in pressurized gases
Microbial air sampler microbiology clean room

HOW DOES A MICROBIAL AIR SAMPLER WORK?

Wie funktioniert ein Luftkeimsammler

CRITERIA FOR SELECTION OF A MICROBIAL AIR SAMPLER ACCORDING TO ISO 14698-1

With so many different makes and models of microbial air samplers on the market, it is worthwile to study their specifications carefully before making a purchase decision. ISO 14698-1 recommends that the impaction rate of the air sampler be high enough to allow the collection of viable particles up to about 1 µm. On the other hand, the velocity must be slow enough to ensure the viability of viable particles. A filtered air outlet is another essential criterion.

Faster flow rate models do not have better collection efficiency. The key factor for active air sampling in sterile applications and for continuous monitoring of clean rooms is the d50 value. Media can dry out faster at higher flow rates, which requires more media plate changes.

  • Small dimensions - little space requirement
  • Construction material: housing and probe head made of stainless steel and therefore easily autoclavable
  • Easy to wipe - no gaps, button switches or particle traps
  • Media plate holder - easily adjustable holder mechanism; The diameter of the media trays vary from +/- 1 mm to 3 mm
  • HEPA filtered air exhaust - captures viable particles that have not been impacted
  • Touchscreen interface - reduces contact and potential particle generation
  • Battery operated for better mobility of portable devices
  • Remote sampling options - offers more flexibility
  • Compressed gas connection for testing gases according to ISO 8573
  • Measure particle sizes down to 1 µm to meet the requirements of ISO 14698

MICROBIAL AIR SAMPLER MODELS

ActiveCount 100
Microbial Air Sampler ActiveCount 100

Flow rate 100 l/min

ActiveCount 100H
Microbial Air Sampler ActiveCount 100H

Flow rate 100 l/min with HEPA filter

ActiveCount 25H
Microbial Air Sampler ActiveCount 25H

Flow rate 25 l/min with HEPA Filter

ACCESSORIES FOR COMPRESSED GAS AND REMOTE SAMPLING

Gas sampler
Image
Remote sampler
Image

MICROBIAL AIR SAMPLER SPECIFICATIONS


  • Luftdurchfluss 100 l/min
  • Standard 90 mm Petrischalen mit Justiermöglichkeit
  • 8,9 cm Farb-Touchscreen
  • Programmierbare Probenvolumina (8), Benutzernamen (50) und Ortsnamen (400)
  • Kontinuierliche und periodische Proben-Modi
  • Einstellbare Start-und Zyklusverzögerungen
  • Durchfluss Alarmierung
  • Datenübertragung per USB-Stick
  • Abwischbar, autoklavierbarer Probenahmekopf; geeignet für sterile Bedingungen
  • AC / Batterie, 6h bei normalem Gebrauch, 2h Ladezeit
  • Abmessungen: 19.5 x 12.1 x 12.1 cm, Gewicht: 2,63 kg
  • Validiert durch ein unabhängiges Institut, erfüllt die ISO 14698-1 Norm
  • Hohe physikalische und biologische Erfassungseffizienz gemäss ISO 14698-1
  • Optional: IQ / OQ-Dokumentation, Stativ, Druckgas-Probenehmer
  • Air flow 100 l / min
  • Standard 90 mm Petri dishes with adjustment option
  • 8.9 cm color touchscreen
  • Programmable sample volumes (8), user names (50) and place names (400)
  • Continuous and periodic sample modes
  • Adjustable start and cycle delays
  • Flow alert
  • Data transfer via USB stick
  • Wipeable, autoclavable sampling head; suitable for sterile conditions
  • AC / battery, 6h with normal use, 2h charging time
  • Dimensions: 19.5 x 12.1 x 12.1 cm, weight: 2.63 kg
  • Validated by an independent institute, meets the ISO 14698-1 standard
  • High physical and biological detection efficiency according to ISO 14698-1
  • Optional: IQ / OQ documentation, tripod, pressurized gas sampler