REFERENCE THERMOMETER
FLUKE 1523/1524
REFERENCE THERMOMETERS FOR HIGHLY ACCURATE CALIBRATIONS
The Fluke 1523 or Fluke 1524 reference thermometers are used for calibration with a temperature standard or for measuring the process temperature with high accuracy. It measures, stores and graphically displays measurement data from resistance thermometers, thermocouples and thermistors. The reference thermometer has an excellent accuracy of up to ±0.011 °C with a PRT probe. The data can be logged and statistically evaluated; all in one handheld device that you can take with you wherever you go.
REFERENCE THERMOMETERS FOR VARIOUS APPLICATIONS
The Fluke reference thermometers are designed for field applications and laboratory measurements. The Fluke 1523 has one measurement channel and the Fluke 1524 has two measurement channels.
Calibration, loop testing, compliance testing, troubleshooting, maintenance, and repair are some of the varied tasks that require an accurate thermometer. The Fluke 1523 and Fluke 1524 thermometers are handy and accurate temperature references in calibration baths, dry block calibrators, immersion sleeves, clean rooms, freezers, autoclaves or other equipment that needs to be calibrated, checked or serviced.
Calibration with Fluke 1523
Reference thermometer Fluke 1524
PRECISE TEMPERATURE MEASUREMENT AND EASY HANDLING
Special precision resistors and a highly stable reference voltage make the reference thermometer insensitive to ambient temperatures. Together with a connected resistance temperature sensor (RTD), an accuracy of up to ±0.011 °C can be achieved.
Reference probes can be connected quickly and easily. A memory chip built into the INFO-CON connector stores the calibration information of the connected probe. When the reference is inserted, the calibration constants are loaded into the thermometer to ensure the correct temperature conversion for accurate and problem-free measurements.
DISPLAY MEASUREMENT DATA AND ANALYZE TRENDS
The Fluke 1523 can record 25 measurements and statistics. The Fluke 1524 model also has a real-time clock and a data memory for 15,000 measurement data, which are provided with a time and date stamp. The measurement data are shown graphically on the display; so you can immediately identify trends and see whether a temperature is stable.
The device also has statistical functions such as min / max values, standard deviation and average. The measurement data can also be downloaded to a PC for further analysis.
Referenzthermometer Fluke 1523
FLUKE CALIBRATION
Bakrona is the authorized representative of Fluke Calibration for industrial temperature calibration in Switzerland and Liechtenstein. We offer our customers in the pharmaceutical, biotech, aviation and food industries a comprehensive service. From advice on new devices to revision and calibration of existing calibrators and references for the parameters temperature, pressure and relative humidity.
REFERENCE THERMOMETER SPECIFICATIONS
1523 | 1524 | |||||
---|---|---|---|---|---|---|
Input channels | 1 | 2 | ||||
Logging | 25 readings with statistics | 25 readings with statistics | ||||
Additional data memory | 15,000 measurements with time/date stamp | |||||
Sample interval | 1 second | 1 second | ||||
Sensor types | PRTs, RTDs, Thermistors, and Thermocouples | PRTs, RTDs, Thermistors, and Thermocouples | ||||
Thermocouple types | C, E, J, K, L, M, N, T, U, B, R, S | C, E, J, K, L, M, N, T, U, B, R, S | ||||
Operating temperature | '-10°C to 60°C (Best accuracy 13°C to 33°C) | '-10°C to 60°C (Best accuracy 13°C to 33°C) | ||||
Power requirements | 3 AA alkaline batteries | 3 AA alkaline batteries | ||||
Size | 96 x 200 x 47 mm | 96 x 200 x 47 mm | ||||
Weight | 0,65 kg | 0,65 kg | ||||
Environmental conditions for best accuracy | 13 °C to 33 °C | 13 °C to 33 °C | ||||
Best possible measurement accuracy with PRT probe at different temperatures | ||||||
-200 °C | ±0,014 °C | ±0,014 °C | ||||
0 °C | ±0,021 °C | ±0,021 °C | ||||
100 °C | ±0,027 °C | ±0,027 °C | ||||
300 °C | ±0,040 °C | ±0,040 °C | ||||
420 °C | ±0,050 °C | ±0,050 °C | ||||
Three types of sensors
- PRTs: -200 ° C to 1000 ° C.
- Thermocouples -200 ° C to 2315 ° C.
- Precision thermistors: -50 ° C to 150 ° C
Accuracy
- PRTs: up to ±0.011 °C.
- Thermocouples: ±0.24 °C for J, K, L, M.
- Precision thermistors: ±0.002 °C.
Fast Mode
- PRTs: 0.45 seconds per sample
- Thermocouples: 0.3 seconds per sample
- Precision thermistors: 0.3 seconds per sample
Graphic display
- 128x64 backlit LCD graphic display
- Draw and scale trends in real time
- Simultaneous two-channel reading