AEROSOL MANIFOLD SYSTEM

Aerosol Particle Measurement from Lighthouse


AEROSOL MANIFOLD SYSTEM for air sampling at multiple locations

MANIFOLD SYSTEMS FOR AIR SAMPLING AT MULTIPLE LOCATIONS


Air sampling at multiple locations within a clean area can be carried out effectively with an aerosol manifold system and a single particle counter, unless a continuous particle monitoring is required.

UM-II AND CONTROLLER


  • Collects data from up to 32 locations
  • Sample tubing per port up to 35 m
  • Constant nominal flowof3CFM (9 l/min) at eachsampling point. Minimizesgravitationalsettling.
  • User programmable data sampling
  • Samples in sequential or random modes
  • Short purge times
  • Alarm in case of a low-flow condition
  • 304 stainless steel construction
  • Controller with built-in 14.5 cm touchscreen
  • Compatible with most particle counters at 1 cfm
  • Modbus RS-485 communication
  • Direct connection to building automation and factory management systems possible
Manifold to collect data at 32 locations

Affordable solution for monitoring of large areas

Mini Manifold for sequential particle monitoring

Sequential particle monitoring of small areas

MINI MANIFOLD


  • Monitor up to 6 locations
  • Small manifold sequencing system with built-in controller
  • Continuous purge including sample line
  • Available with 1 cfm or 0.1 cfm flow rate
  • Stainless steel construction
  • User-defined port sequence, purge, sample and hold time
  • Switches from one sampling point to the next in less than one second
  • Modbus RS-485 communication
  • Interface to a computer system, process tool, building automation and factory management system

MANIFOLD FOR MULTI-LOCATION AIR SAMPLING WITH ONE PARTICLE COUNTER

Manifold systems have been used for particle monitoring in controlled environments for many years. Unless continuous particle monitoring is required, air sampling from multiple locations within a clean area can be effectively performed with an aerosol dispenser system and just one particle counter.

The manifold distribution system uses a particle counter and a mechanical system to align the particle counter's sample inlet with the sample line to be sampled. Manifold systems come in different sizes depending on the number of sampling points required. In general, the distribution systems range from 5, 10, 20 to 30 sampling points.

Manifold systems can be connected to particle counters with flow rates of 0.1cfm (2.83lpm) or 1.0cfm (28.3lpm).

Manifold features

  • Collects data from up to 32 locations
  • Sample tubing per port up to 35 m
  • Constant nominal flowof3CFM (9 l/min) at eachsampling point. Minimizesgravitationalsettling.
  • User programmable data sampling
  • Samples in sequential or random modes
  • Short purge times
  • Alarm in case of a low-flow condition
  • 304 stainless steel construction
  • Controller with built-in 14.5 cm touchscreen
  • Compatible with most particle counters at 1 cfm
  • Modbus RS-485 communication
  • Direct connection to building automation and factory management systems possible

Manifold particle measurement
REQUEST QUOTE