WIRELESS DATALOGGERS

DATALOGGER FOR THE VALIDATION AND ROUTINE CHECKS OF THERMAL PROCESSES
Temperature, pressure and humidity datalogger for temperatures ranging from -90 ° C to +150 ° C respectively for a pressure range from 1 mbar to 10 bar abs. Thus, the datalogger have a wide range of applications and are especially suited for the use in autoclaves (steam sterilization).
THE RIGHT DATALOGGER FOR EACH OF YOUR APPLICACTIONS

TRACKSENSE PRO
Versatile datalogger with exchangeable sensors and optional online data transmission

TRACKSENSE COMPACT
Datalogger with fixed temperature and pressure sensors, dedicated to specific applications

TRACKSENSE MINI
Small dataloggers for temperature and pressure measurements in products and in small containers

TRACKSENSE FRIGO
Logger with extra battery capacity for temperature measurement up to -90 ° C in refrigerators & freezers
FIND THE RIGHT DATALOGGER FOR YOUR APPLICATION
TEMPERATURE SENSORS
Single, double or quad sensors in different versions. Special sensors for low and high temperature applications from -196 ° C to +400 ° C

RIGID
Short reaction time thanks to Ø 2 mm; necessary for the evaluation of saturated steam conditions and equilibrium time in autoclaves

BENDABLE
Single and double sensors with small diameter for measurements in small containers such as vials and in products

FLEXIBLE
Single, double and quadruple
sensors with small diameter (1.8 mm). Ideal for measurements in vials and on surfaces in freeze-dryers

HIGH TEMPERATURE
Single and double sensors for high temperature applications up to 400 °C such as dry heat ovens and depyrogenation
PRESSUE, HUMIDITY AND CONDUCTIVITY SENSORS

PRESSURE & VACUUM
Pressure sensor to check saturated steam conditions in autoclaves. Vacuum sensor for low pressure applications such as freeze drying

HUMIDITY
Monitoring of the humidity in stability applications such as incubators and stability chambers over prolonged periods. Optional live data .

HUMIDITY (ETO / H2O2)
Humidity sensor with protecting filter to avoid drift of sensor in harsh and corrosive environments, such as in ETO or H2O2 sterilization.

CONDUCTIVITY
Monitoring of industrial processes and validation of washing & disinfection processes, for which the EN ISO 15883:2009 norm is applicable
TRACKSENSE SYSTEM COMPONENTS

READER STATION
Reader station with inductive data transmission for simultaneous readout of the loggers

RADIO MODULE
Process information in real time thanks to the optional wireless module for TrackSense Pro Logger

ACCESSORIES
Feedthroughs, fixations, thermal barriers etc. for the correct placement of the sensor measuring tip
SPECIFICATIONS & APPLICATIONS
Specifications | Pro | Compact | Mini | Frigo |
---|---|---|---|---|
Temperature range: | Pro: -50 to +150 °C (Pro X: -80 °C to 150 °C) | Compact: -30 °C to +140 °C (Compact UX: -80 °C to 140 °C) | 0 to +140 °C | -90 °C to +85 °C |
Pressure range: | 0.001 mBar to 10 bar abs. | 10 mbar to 6 bar abs. | 0 mbar to 10 bar abs. | 1 mbar to 10 bar abs. |
Temperature accuracy: | ± 0.05 °C | ± 0.1 °C | ±0.05 °C | ±0.1 °C |
Pressure accuracy: | ± 0.25 % of full scale | ± 0.25 % of full scale | N/A | N/A |
Volume: | N/A | 17.1 cm³ | 3.6 cm³ | 29.4 cm³ |
Diameter: | 25 mm | 25 mm | 20 mm | 25 mm |
Length: | 44 mm | 35 mm | 12 mm | 60 mm |
Memory (memory points): | 60.000 | 14.500 (temp) / 7.200 (pressure) | 30.000 | 60.000 |
Sensor element: | Pt1000 | Pt1000 | Pt1000 | Pt1000 |
Position of sensor element: | 3 mm behind sensor tip | 3 mm behind sensor tip | 3 mm behind sensor tip | 3 mm behind sensor tip |
Battery (exchangeable by user): | Ellab Lithium battery | Ellab Lithium battery | Ellab Lithium battery | Ellab Lithium battery size AA |
Parameters & Options | ||||
Temperature measurement | x | x | x | x |
Pressure measurement | x | x | ||
Humidity measurement | x | |||
Conductivity measurement | x | |||
Radio transmission (online data) | x | |||
Exchangeable sensors | x |